Criteria | Supporting Features | Remarks (e.g., definition, equivalent facilitation, scope of support provided) |
1194.21(a) When software is designed to run on a system that has a keyboard, product functions shall be executable from a keyboard where the function itself or the result of performing a function can be discerned textually. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - ability to perform functions from the keyboard only
- logical movement of focus through the controls
- proper operation of unique keystrokes and access keys, including those listed in the product documentation.
Exception(s): - Member Formula editor toolbar icons under Member Properties (Properties of Statistics) are not keyboard accessible. Bug ID: 13835429
- Screen Reader announces additional text “out of table” when tabbing through members in the Member Properties pane. Bug ID: 13835178
- Screen Reader not announcing activation key (F2) for Dimensions column cells. Bug ID: 13860974
- Shift+Tab does not display app summary details under Application Library. Workaround is to press Shift+Tab then space bar to highlight the application and then press Shift+F10 and refresh the view. Bug ID: 13834992
- Shift+tab behavior is inconsistent in Member Selector. The focus may or may not go to the previous field. Bug ID: 10262310
- Any server side call or page refresh add application takes focus to the global toolbar Help link. E.g. in the Application Library Folder Options. Bug ID: 13861489
- Inconsistent focus when editing application, the focus moves to Shared library instead of Application View. Bug ID: 13861044
- Non-contiguous selections (multi select using keyboard hot keys) do not work with a screen reader on all BI trees components. Workaround is to work with individual tree items.
- Horizontal scroll doesn't work with arrow keys throughout the application
- Shift+F10 on the app in app lib doesn't open the current application context menu but instead opens the last focused application. Bug ID: 9095391
- In App upgrade wizard, the progress indicator (loading) is in the table, focus is not read by screen reader.
|
1194.21(b) Applications shall not disrupt or disable activated features of other products that are identified as accessibility features, where those features are developed and documented according to industry standards. Applications also shall not disrupt or disable activated features of any operating system that are identified as accessibility features where the application programming interface for those accessibility features has been documented by the manufacturer of the operating system and is available to the product developer. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for response to the following operating system accessibility features: - Sticky Keys, Slow Keys, Filter Keys, Bounce Keys, and Toggle Keys
- High Contrast and Large Print themes.
|
1194.21(c) A well-defined on-screen indication of the current focus shall be provided that moves among interactive interface elements as the input focus changes. The focus shall be programmatically exposed so that assistive technology can track focus and focus changes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Visual indication of the position of the cursor within text, and visual indication of the focused component, including with the High Contrast and Large Print theme.
Exception(s): - Shift+Tab does not display app summary details under Application Library. Workaround is to press Shift+Tab then space bar to highlight the application and then press Shift+F10 and refresh the view. Bug ID: 13834992
- Inconsistent focus highlight in application provided High Contrast mode. E.g. Focus is highlighted in grey in Grid Editor and Property Grid screens
|
1194.21(d) Sufficient information about a user interface element including the identity, operation and state of the element shall be available to assistive technology. When an image represents a program element, the information conveyed by the image must also be available in text. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification
- including object state change on selection (e.g., folder open on selection)
Exception(s): - Screen Reader announces additional text “out of table” when tabbing through members in the Member Properties pane. Bug ID: 13835178
- Screen reader announces additional info (“Enter key activates OK button”) under Dimension Mapping > Insert Filter Definition dialog box. Bug ID: 13860874, 10258069
- Member Selector > Search Tab: Screen reader does not announce the “Find” text field label. Bug ID: 10262310
- Alt Text for Search and Adv Search missing under Member Selector. Bug ID: 10262310
- Filter criteria Member Selection> Find member icons: Screen reader announce entire image url. Bug ID: 10258069
- Non-contiguous selections (multi select using keyboard hot keys) do not work with a screen reader on all BI trees components. Workaround is to work with individual tree items.
- In App upgrade wizard, the progress indicator (loading) is in the table, focus is not read by screen reader.
- Screen reader unable to read the Folder and Dimensions image in Dim Library -> Shared Library
|
1194.21(e) When bitmap images are used to identify controls, status indicators, or other programmatic elements, the meaning assigned to those images shall be consistent throughout an application's performance. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification
- including object state change on selection (e.g., folder open on selection
Exception: - Alt Text for Search and Adv Search missing under Member Selector. Bug ID: 10262310
|
1194.21(f) Textual information shall be provided through operating system functions for displaying text. The minimum information that shall be made available is text content, text input caret location, and text attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | Textual information is provided through standard HTML markup and controls. The browser is responsible for making operating system function calls. |
1194.21(g) Applications shall not override user selected contrast and color selections and other individual display attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Windows or other OS-level color settings are not over-ruled by product
Exception: - Inconsistent high contrast in the following pages: application library tabs, application creation wizard > application type tab, dimension library tabs, grid editor, property grid, data synchronization, application creation wizard, mapping table designer, and configure interface data source. Bug IDs: 13835148, 13860974, 13861044
|
1194.21(h) When animation is displayed, the information shall be displayable in at least one non-animated presentation mode at the option of the user. | Not Applicable | The product contains no animation. |
1194.21(i) Color coding shall not be used as the only means of conveying information, indicating an action, prompting a response, or distinguishing a visual element. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Alt means are used for conveying color related information
Exception(s): - There is reliance on color for validation error messages in the Validate Mappings step under Mapping Table Designer. Screen reader doesn’t announce what the error is. Bug ID: 13835014
- The following screens use color coding which doesn't support an alt way to access info: grid editor, alias dialog, name level generation
|
1194.21(j) When a product permits a user to adjust color and contrast settings, a variety of color selections capable of producing a range of contrast levels shall be provided. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - product offers single color contrast setting (high contrast)
- contrast setting is consistent through the user session
- Windows or other OS-level color settings are not over-ruled by product
Exception(s): - Inconsistent high contrast in the following pages: application library tabs, application creation wizard > application type tab, dimension library tabs, grid editor, property grid, data synchronization, application creation wizard, mapping table designer, and configure interface data source. Bug IDs: 13835148, 13860974, 13861044
- Inconsistent focus highlight in application provided High Contrast mode. E.g. Focus is highlighted in grey in Grid Editor and Property Grid screens
|
1194.21(k) Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - elements that flash or blink between 2 Hz and 55 Hz
|
1194.21(l) When electronic forms are used, the form shall allow people using assistive technology to access the information, field elements, and functionality required for completion and submission of the form, including all directions and cues. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - User interface component labels are associated with the fields they are labeling.
- Edit text fields have a label associated with them.
- Label associations and form controls are exposed to assisstive technologies
- Reading of screen text
- Screen elements under magnification retain readability and are recognizable
- AT product successfully tracks cursor focus
Exception(s): - Member Selector > Search Tab: Screen reader does not announce the “Find” text field label. Bug ID: 10262310
- Non-contiguous selections (multi select using keyboard hot keys) donot work with a screen reader on all BI trees components. Workaround is to work with individual tree items.
- In App upgrade wizard, the progress indicator (loading) is in the table, focus is not read by screen reader.
|