Criteria | Supporting Features | Remarks (e.g., definition, equivalent facilitation, scope of support provided) |
1194.21(a) When software is designed to run on a system that has a keyboard, product functions shall be executable from a keyboard where the function itself or the result of performing a function can be discerned textually. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Ability to perform functions from the keyboard only
- Logical movement of focus through the controls
- Proper operation of unique keystrokes and access keys, including those listed in the product documentation.
Exceptions: - Screen reader doesn't announce the label "Opening Form" or "Opening Task List" when opening a form or task list that takes time. Bug ID: 9059986
- Every page refresh (server-side call) like saving data or changing smart lists takes focus out of the data entry forms. Bug ID: 13775131
- Column Header isn't associated with the expand/collapse action in all data entry forms. The expand/collapse icon precedes the column headers making it difficult for users to know what columns they will be expanding/collapsing. Bug ID 13637387
- Following hot keys don't work in screen reader mode. Workaround: Tab keys work.
Ctr+Shift+B - is not invoking Add Sibling in Dimension Editor and Task Lists Ctrl + 6 - is not invoking Add Summary Time Period Alt + M - Toggle focus on Member selection between currency, scenario, Version (In Currency conversion) Ctrl+Shift+Arrow Left / Ctrl+Shift+Arrow Right - Move the selected column to the left or right - Navigation through the left-hand pane to select form or task list requires the end user to press the down arrow until they reach the desired task. Not able to navigate directly to the parent (folder) to find the task. Bug ID: 16402997
- On opening a form with tabs then using Ctrl+Shift+T to move from the current tab to the next tab, the screen reader control will be on the previous tab and announce it again. Bug ID: 16410412
- The left hand task list accordion is shown twice upon invoking screen reader mode. Bug ID: 13637414
- In the simplified interface, there is limited support for navigation using short-cut keys. User will need to use tab and Shift+tab key as primary navigation key. Bug ID: 19276639
- In non-screen reader mode, when working with tree controls, e.g Task lists, data forms, focus does not move to lower level elements and hence these cannot be invoked using keyboard only navigation. Bug ID: 19467568
- In the simplified interface, tab order is not correctly defined. Action items for screens, e.g. save, cancel, finish, next etc., are on the top of the page and hence these are first in tab order, where as user would want to complete other operations on the page and then reach these action buttons. Bug ID: 19362240
- In the simplified interface, there is limited support for Accelerator Keys. Many of the commonly used actions, e.g. Refresh, Actions, Save, Create and Close, Clear, Apply, Schedule and Next, etc., would need to be invoked using tab or Shift+Tab keys. Bug ID: 19274748
- In the simplified interface of Planning, keyboard navigation does not work on supporting details page. Bug ID: 19364819
- In the simplified interface, there are multiple issues when navigating to Financial reports. Bug ID: 19431191
- In the simplified interface of Planning, the first button on all pages does not show highlighted when focus is moved to it. Bug ID: 19187169
- In Planning data forms, page drop downs for dimensions are shown as disabled even when the selected values can be changed using member selector. Bug ID: 19365122
- In Tree view or Tree table type components e.g. Dimension editor, Task lists, leaf level members without any children are also shown with the expand icon. This confuses the user to think that these items have a child and they need to click or expand even when these are leaf level members. Bug ID: 17218454
- In the Planning simplified interface, if a popup dialogue does not have close button on it, it can not be closed. Bug ID: 19300287
- In non-screen reader mode, focus does not move to confirmation or error message dialogs. Bug ID: 19467568
- In Screen reader mode, activating an error message in the Data Validation Summary popup doesn't take focus back to the cell in the planning gird showing validation error. Bug ID: 13713254. Workaround: users have to tab through each cell to find out which cells errored out.
|
1194.21(b) Applications shall not disrupt or disable activated features of other products that are identified as accessibility features, where those features are developed and documented according to industry standards. Applications also shall not disrupt or disable activated features of any operating system that are identified as accessibility features where the application programming interface for those accessibility features has been documented by the manufacturer of the operating system and is available to the product developer. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for response to the following operating system accessibility features: - Sticky Keys, Slow Keys, Filter Keys, Bounce Keys, and Toggle Keys
- High Contrast and Large Print themes.
|
1194.21(c) A well-defined on-screen indication of the current focus shall be provided that moves among interactive interface elements as the input focus changes. The focus shall be programmatically exposed so that assistive technology can track focus and focus changes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Visual indication of the position of the cursor within text, and visual indication of the focused component, including with the High Contrast and Large Print theme.
Exceptions: - Every page refresh (server-side call) like saving data or changing smart lists takes focus out of the data entry forms. Bug ID: 13775131
|
1194.21(d) Sufficient information about a user interface element including the identity, operation and state of the element shall be available to assistive technology. When an image represents a program element, the information conveyed by the image must also be available in text. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification including object state change on selection (e.g., folder open on selection)
Exception: - On opening a form with tabs then using Ctrl+Shift+T to move from the current tab to the next tab, the screen reader control will be on the previous tab and announce it again. Bug ID: 16410412
|
1194.21(e) When bitmap images are used to identify controls, status indicators, or other programmatic elements, the meaning assigned to those images shall be consistent throughout an application's performance. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification including object state change on selection (e.g., folder open on selection)
|
1194.21(f) Textual information shall be provided through operating system functions for displaying text. The minimum information that shall be made available is text content, text input caret location, and text attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | Textual information is provided through standard HTML markup and controls. The browser is responsible for making operating system function calls. Exceptions: - With browser display re-sized to 200%, a portion of the data forms is not rendered correctly when user scrolls through it. Bug ID: 19276427
|
1194.21(g) Applications shall not override user selected contrast and color selections and other individual display attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Windows or other OS-level color settings are not over-ruled by product
Exceptions: - When working with Operating System level high contrast mode enabled icons like expand, collapse, search etc. are not visible. Bug ID: 19284384
- In the simplified interface of Planning, some of the icons e.g. dashboards, search icons, are not visible in high contrast mode. Bug ID: 19343390 & 19277305
- In Data Forms, when working with Operating System level high contrast mode enabled, selected controls like data cells, page drop downs, etc. are not distinguishable from other controls, which are not selected. Bug ID: 18504729
- In the simplified interface of Planning, List view components, e.g. selecting data forms when creating dashboard, do not show the focus on the selected item in high contrast mode. Bug ID: 19343457
|
1194.21(h) When animation is displayed, the information shall be displayable in at least one non-animated presentation mode at the option of the user. | Not Applicable | The product contains no animation. |
1194.21(i) Color coding shall not be used as the only means of conveying information, indicating an action, prompting a response, or distinguishing a visual element. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Alt means are used for conveying color related information
|
1194.21(j) When a product permits a user to adjust color and contrast settings, a variety of color selections capable of producing a range of contrast levels shall be provided. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Product offers single color contrast setting (high contrast)
- Contrast setting is consistent through the user session
- Windows or other OS-level color settings are not over-ruled by product
|
1194.21(k) Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Elements that flash or blink between 2 Hz and 55 Hz
|
1194.21(l) When electronic forms are used, the form shall allow people using assistive technology to access the information, field elements, and functionality required for completion and submission of the form, including all directions and cues. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - User interface component labels are associated with the fields they are labeling.
- Edit text fields have a label associated with them.
- Label associations and form controls are exposed to assisstive technologies
- Reading of screen text
- Screen elements under magnification retain readability and are recognizable
- AT product successfully tracks cursor focus
Exceptions: - Missing lables for: Business Rules RTP window - Prompt text, User Preferences (all tabs), Search button on Planning Unit Hierarchy screen & substitution var window in Manager variables, Map Reporting Object - Member selection column, Exchange Rate Table, Copy Data Members column, and Manage Variables - check boxes in Variable window. Bug ID 13871180
|