Criteria | Supporting Features | Remarks (e.g., definition, equivalent facilitation, scope of support provided) |
1194.21(a) When software is designed to run on a system that has a keyboard, product functions shall be executable from a keyboard where the function itself or the result of performing a function can be discerned textually. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - ability to perform functions from the keyboard only
- logical movement of focus through the controls
- proper operation of unique keystrokes and access keys, including those listed in the product documentation.
Exceptions: - Sometimes focus is lost while tabbing or accessing certain components. - Bug ID: 16491902 [Workaround: Access keys (Alt+1, Alt+2, Alt+3) are provided to navigate to top of left, mid, right most panels respectively whenever focus is lost, so that it's possible to tab back from the top of the required panel.(Documented in accessibility guide)]
- Consolidation menu items can't be opened via keyboard unless focus is on the content area. Also, focus is not set on any newly opened tab. - Bug IDs: 17182768, 16430705 [Workaround: Immediately after opening a Consolidation application, press Alt+2 to set the focus to the content area. After setting the focus, you can access items from the Consolidation menu. Whenever a new tab is opened, press Alt+2, so that the focus moves to the opened tab and reads the tab title. Documented in accessibility guide]
- An exception from Oracle Application Development Framework is thrown in process control - validation dialog when Suppress "NoData" option is selected. - Bug ID: 17209698
- In normal mode, using keyboard, it's not possible to enter cell text/line item details in data forms/data grids, can't move dimension from Point of View (POV) bar to a row or column in data grid designer, can't delete row/column from data form designer. - Bug IDs: 17203143, 17202510, 17195850
- Using keyboard, member selector is not accessible from Manage Task Flow screen, access rights for an user (administration module) can't be changed. - Bug IDs: 16477372, 17234392
- Can't access scroll bar in Journal Manage/Template panels & log windows of load screens using keyboard. - Bug ID: 17227702
- In Screen Reader mode, it's not possible to choose options correctly in Extended Select Many list boxes & for panels containing multiple selection of check boxes that can be shuttled to another panel, the focus is not properly visible around the check box - Bug Ids: 16489784, 16478158
- Can't open links displayed within Show Detail dialog in Monitor Intercompany screen, Member Search Link next to Owner/Owned fields are not visible in Equity Pick Up screen, Bug IDs: 17210421, 17217607
- In Screen Reader mode, it's not possible to select row/column in form designer, so that the row/column option are displayed In the right most panel - Bug ID: 17226558 [Workaround: Select dimension link in row/column which opens Member Selector. Select ok or cancel button in Member Selector. Row/Column options will be available in the right most panel]
- OK/Cancel access keys missing in Manage Intercompany screen for Manage Columns & Reorder dialogs and Update dialog of Load Screens. - Bug IDs: 17203541, 17246642 [Workaround: Tab to OK/Cancel button & invoke it.]
- Access Key (i) for accessing the Actions menu is missing in Intercompany report editor. - Bug ID: 17203457 [Workaround: Press Alt+2 & tab till the Actions link is accessed.]
- Tabbing doesn't directly go to Show Detail panel In Show Detail tree of Intercompany Monitor page. - Bug ID: 17210557
- Few menu items are not listed in Actions menu of Journals screens in Screen reader mode. - Bug ID: 17218077
- Few popups can't be closed with Escape button. - Bug ID: 17327422 [Workaround: Use Alt+l access key to close the popup]
|
1194.21(b) Applications shall not disrupt or disable activated features of other products that are identified as accessibility features, where those features are developed and documented according to industry standards. Applications also shall not disrupt or disable activated features of any operating system that are identified as accessibility features where the application programming interface for those accessibility features has been documented by the manufacturer of the operating system and is available to the product developer. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for response to the following operating system accessibility features: - Sticky Keys, Slow Keys, Filter Keys, Bounce Keys, and Toggle Keys
- High Contrast and Large Print themes.
|
1194.21(c) A well-defined on-screen indication of the current focus shall be provided that moves among interactive interface elements as the input focus changes. The focus shall be programmatically exposed so that assistive technology can track focus and focus changes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Visual indication of the position of the cursor within text, and visual indication of the focused component, including with the High Contrast and Large Print theme.
Exceptions: - Pressing Alt+3 doesn’t take the focus to the right most panel in 'Intercompany Transaction by ID' & 'Intercompany Transaction by Account' report editors. - Bug ID: 17211616. [Workaround: Tab through the end of mid panel & then further tabbing takes the focus to the right most panel.]
- When an Alert/Information/Error/Warning popup dialog is displayed, focus goes to the first active component on the dialog. Hence the message & title is not read. - Bug ID: 16491202. [Workaround: Message & title in some dialogs can be read by using Virtual Cursor keys, but it works for some dialogs & not all.]
- Sometimes, focus is lost when changing dimension from the dimension drop down in a Member Selector. - Bug ID: 17217985 [Workaround: Cancel the Members Selector dialog by pressing Alt+l and then select the dimension from the POV bar for which the member is to be selected.}
|
1194.21(d) Sufficient information about a user interface element including the identity, operation and state of the element shall be available to assistive technology. When an image represents a program element, the information conveyed by the image must also be available in text. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification including object state change on selection (e.g., folder open on selection)
Exceptions: - Few icons used for sorting & few hidden images doesn't have Alternate text defined in Task Flows. Also, there are a couple of redundant decorative images displayed in data grid screen - Bug IDs: 17261065, 17240567
|
1194.21(e) When bitmap images are used to identify controls, status indicators, or other programmatic elements, the meaning assigned to those images shall be consistent throughout an application's performance. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Meaningful icon/image/object identification including object state change on selection (e.g., folder open on selection)
Exceptions: - Few icons used for sorting & few hidden images doesn't have Alternate text defined in Task Flows. Also, there are a couple of redundant decorative images displayed in data grid screen - Bug IDs: 17261065, 17240567
|
1194.21(f) Textual information shall be provided through operating system functions for displaying text. The minimum information that shall be made available is text content, text input caret location, and text attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | Textual information is provided through standard HTML markup and controls. The browser is responsible for making operating system function calls. |
1194.21(g) Applications shall not override user selected contrast and color selections and other individual display attributes. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Windows or other OS-level color settings are not over-ruled by product
|
1194.21(h) When animation is displayed, the information shall be displayable in at least one non-animated presentation mode at the option of the user. | Product has been developed to conform to this standard subject to the remarks on the right. | The product contains no animation. |
1194.21(i) Color coding shall not be used as the only means of conveying information, indicating an action, prompting a response, or distinguishing a visual element. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - Alternate means are used for conveying color related information
|
1194.21(j) When a product permits a user to adjust color and contrast settings, a variety of color selections capable of producing a range of contrast levels shall be provided. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - product offers single color contrast setting (high contrast)
- contrast setting is consistent through the user session
- Windows or other OS-level color settings are not over-ruled by product
|
1194.21(k) Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - elements that flash or blink between 2 Hz and 55 Hz
|
1194.21(l) When electronic forms are used, the form shall allow people using assistive technology to access the information, field elements, and functionality required for completion and submission of the form, including all directions and cues. | Product has been developed to conform to this standard subject to the remarks on the right. | The product was tested for: - User interface component labels are associated with the fields they are labeling.
- Edit text fields have a label associated with them.
- Label associations and form controls are exposed to assistive technologies
- Reading of screen text
- Screen elements under magnification retain readability and are recognizable
- AT product successfully tracks cursor focus
Exceptions: - Labels missing for few fields in Intercompany Transaction Report, Email Alert screen, Data Form Designer, filter components in Journals Manage page, Intercompany Period & Reason Codes pages for fields belonging to a table. - Bug IDs: 17259288, 17254759, 17246246, 17259269, 17253935, 17253854
- Check box labels in Manage Data screen are not read, label for Description is not read in Task Flow screen. - Bug IDs: 17216448, 17239952 [Workaround is to use Virtual PC Cursor Keys.]
- On Saving a document, the screen reader reads out a lengthy URL till the Save operation is complete. Also, there are few hidden links that might receive focus during navigation.- Bug IDs: 17211676, 17247076
- Transaction Date Calendar link in Intercompany Manage screen is missing in Screen Reader mode. - Bug ID: 17326727 [Workaround: It's possible to manually enter date in MM/DD/YYYY format]
|